Add: Home >> Gas Detection Schedule
List of the combustible/ vapor gases
Gas types Molecular Formula Explosive limit£¨£¥Vol£© Limit Alarm reference value£¨£¥Vol/25£¥LEL£©
Methane CH4 5.3 1.325
Ethane C2H6 3.0 0.750
Cyclohexane C6H12 1.2 0.300
Oxirane C2H4O 3.0 0.750
Propane C3H8 2.1 0.525
Isobutane C4H10 1.8 0.450
Pentane C5H12 1.7 0.425
Hexane C6H14 1.2 0.300
Heptane C7H16 1.1 0.275
Isooctane C8H18 1.0 0.250
Ethylene C2H4 2.7 0.675
Acetylene C2H2 2.1 0.525
Methanol CH3OH 5.5 1.375
Ethanol C2H5OH 3.3 0.825
Propanol C3H8O 2.0 0.500
Acetone C3H6O 2.5 0.625
Toluene C7H8 1.2 0.300
Xylene C8H10 1.1 0.275
Ethyl acetate C4H8O2 2.0 0.500
Hydrogen H2 4.1 1.025
Ammonia NH3 15.7 3.925
Diesel - 0.6 0.15
 
Note: The above combustible gases or flammable liquids used by the sensor steam Detecting Theory The catalytic combustion or semiconductor
Other not listed in the table gas Please Call Advisory
 
 
List of the toxic gases
Gas types Molecular Formula Measurement Range£¨ppm) Limit Alarm reference value£¨ppm£©
Carbon monoxide CO 1000 250
Hydrogen sulfide H2S 100/200 25
Ammonia NH3 100 25
Sulfur dioxide SO2 100 25
Nitric oxide NO 100 25
Nitrogen dioxide NO2 20 5
Oxygen O2 30%Vol 17%Vol And 23%
Chlorine CL2 10 2
Chlorine Dioxide CLO2 1 0.2
Hydrogen H2 10000 2000
Hydrogen chloride HCL 50 10
Phosphine PH3 5 1
Hydrogen fluoride HF 10 2
Hydrogen cyanide HCN 100 20
Oxirane C2H4O 20 5
Formaldehyde CH2O 20 5
Ozone O3 5 2
Silane SiH4 50 10
Ethylene C2H4 2000 500
Carbon dioxide CO2 5000/100%Vol 1250/25%Vol
 
Note: The above toxic gas sensor used for Detecting Theory Electrochemical, Carbon dioxide sensor used for the infrared-detection principle .
Other not listed in the table gas Please Call Advisory
 