| GN8010-OUT Bus Control-Output Module |
|
| Click
on View [ Dimension
& Mounting / wiring terminal ] |
| |
| ¡ö
Characteristic£º |
| |
| ¡ñ |
Mod-bus Signal |
¡ñ |
Explosion Prevention Mark Exd¢òCT6 |
|
| ¡ñ |
2 cable entries convenient to install |
¡ñ |
Can drive directly equipments following 500W |
|
| ¡ñ |
Own intellectual
property rights with self-determination |
|
|
|
| |
| ¡ö
Working theory£º |
| |
| GN8010-IN
Bus Control-Input Module, can receive passively switching
signal (e.g. scene manus alarm button),and transform the
signal to mod-bus digital frame, and then sent to GN9000
series gas alarm controller to identify, display and control. |
| |
| ¡ö
Specification£º |
| |
| Output
way |
A group of relay contact outputs(active / passive,
open / closed) |
| output
signal |
Level or pulse signal ( 0-30 seconds, 0 is level
signal output ) Contact capacity 10A 24VDCor 5A
250VAC |
| Setting
Mode |
Dial switch£«key |
| Explosion
Prevention Mark |
Exd¢òCT6 |
| Explosion
Prevention Screw Thread |
3/4"NPT/M20 |
| Communication
Mode |
Modbus |
| Transmission
Distance |
Max. 1200m (2.5mm2 copper cable) |
| Working
Temperature |
-40¡æ¡«+70¡æ |
| Relative
Humidity |
20%¡«95%RH |
| Power
Supply |
24VDC¡À8VDC |
| Maximum
Power supply Consumption |
1W |
| Weight |
Approximately 1Kg |
|
| |